Percutaneous Transluminal Valvuloplasty

NuCLEUS™ and NuCLEUS-X™

NuCLEUS™ and NuCLEUS-X™catheters feature an innovative balloon designed with a waist formed in the middle of the balloon to facilitate positive positioning while holding the balloon in the correct location prior to and during inflation. The NuCLEUS-X™ catheter features a braided inner tubing which provides high inner lumen strength for increased pushability. Upon reaching a specified pressure, the waist will expand between 90% to almost 100% of the rated balloon diameter. The NuCLEUS™ and NuCLEUS-X™ catheters are indicated for PTV of the mitral and aortic valves. The NuCLEUS™ is available in diameters ranging from 10.0-30.0mm and lengths of 3.0-6.0cm, and the NuCLEUS-X™ is available in diameters ranging from 18.0-30.0mm and lengths of 4.0-6.0cm.

Details
COE Image

Pediatric Valvuloplasty

COEfficient™

COEfficient™ balloon catheters were developed in collaboration with Dr. Yashu Coe. The distinguishing feature of this high pressure balloon catheter is its extremely thin profile for a balloon with RBPs as high as 13 ATM.  The COEfficient™ valvuloplasty catheter is engineered for maximum steering and tracking.  The coaxial shaft design provides enhanced column strength and pushability combined with a flexible distal tip for optimum steerability.  The COEfficient™ is available in a range of diameters (4.0-12.0mm) and lengths (2.0-3.0cm) and can be used with even the smallest introducer sheaths (4-7FR).

Details
TyshakX

Percutaneous Transluminal Valvuloplasty

TYSHAK® Line

TYSHAK® balloon catheters were designed in collaboration with Prof Mike Tynan and Prof Shakeel Qureshi.  They are designed with a low profile that delivers high performance. Manufactured from a micro-thin, non-compliant balloon material, these innovative balloon catheters require small introducers. The reduced sheath size helps minimize vessel trauma and entry-site complications. A short, flexible distal tip provides superior maneuverability. With well-defined shoulders and balloon tapers, TYSHAK® catheters glide easily through smaller and difficult-to-negotiate vessels. They are available in a range of diameters (2.0-30.0mm) and lengths (1.0-10.0cm). 

Details
Z-Med II_Z-Med

Percutaneous Transluminal Valvuloplasty

Z-MED(Canada)

Z-MED™ high pressure balloon catheters were designed in collaboration with Dr. Ziyad Hijazi. The Z-MED™ catheters are suitable for percutaneous transluminal valvuloplasty (PTV) and pre-dilatation in transcatheter heart-valve replacement procedures. They feature high rated burst pressures suitable for resistant stenosis and have rapid inflation and deflation times to minimize procedure time and maximize reperfusion.  

Short, flexible distal tips with short balloon tapers aid maneuverability and trackability through tortuous anatomy.  They are available in a wide range of balloon diameters (2.0-40.0mm) and lengths (2.0-10cm).

Z-MED™ catheters are available in Canada through Baylis Medical.

Details

 