The Bonhoeffer
MULTI-TRACK™ System
The NuMED MULTI-TRACK™ Kit is a well
established
innovative system for Mitral Dilatation.
This operator friendly system has the advantages of double balloon
techniques while using a simple, single guidewire approach. The procedure
times easily match those of single balloon techniques while achieving
consistently higher valve areas post dilatation. The mismatch of the
round shape of a single balloon with the oval mitral orifice probably
explains the better results with double balloon dilatation. (Figures A &
B)
 
 
With the guidewire still in place a
MULTI-TRACK™ angiographic catheter is advanced into the left atrium for
the measurement of the transmitral gradient after the dilatation. If
the result is satisfactory all catheters can then be removed, otherwise
balloons of different sizes could still be advanced over the wire.
* The MULTI-TRACK™ system
allows to measure the transmitral gradient even through a single venous
approach. This is obtained by gliding two MULTI-TRACK™ angiographic
catheters along the wire which is positioned in the mitral orifice.
Therefore the arterial approach routinely used for mitral dilatation can
be avoided.
Bonhoeffer
MULTI-TRACK™
Mitral Dilatation Kit Contents
• 1 MULTI-TRACK™
balloon dilatation catheter
(14, 16, 18 or 20 mm in diameter) X 5 cm in length
• 1 matched Rapid Exchange balloon dilatation catheter
• 1 14F, 70cm Dilator
• 1 MULTI-TRACK™
angiographic catheter (5F X 80 cm)
• 1 Super Stiff, preformed 0.035” guidewire
Each kit is packaged in a 120 cm long box
and all catheters are individually pouched thereby maintaining sterile
integrity.
|
Balloon Diameter (MM) |
Balloon
Length
(CM) |
Shaft
Size
(FR) |
Usable
Length
(CM) |
Guide
Wire(Inches) |
Rated
Burst
(ATM) |
Part No.
included
in Kit |
Catalog
Order
No. |
|
14.0 |
5.0 |
7 |
80 |
0.035 |
6.0 |
MTK145 |
BMK14 |
|
14.0 |
5.0 |
7 |
80 |
0.035 |
6.0 |
REMC145 |
|
N/A |
N/A |
5 |
80 |
0.035 |
1000
PSI |
MMTA0580 |
|
N/A |
N/A |
14 |
70 |
0.035 |
N/A |
D1470 |
|
N/A |
N/A |
0 |
210 |
0.035 |
N/A |
J3FC-SS
C 210-035 |
|
16.0 |
5.0 |
7 |
80 |
0.035 |
5.0 |
MTK165 |
BMK16 |
|
16.0 |
5.0 |
7 |
80 |
0.035 |
5.0 |
REMC165 |
|
N/A |
N/A |
5 |
80 |
0.035 |
1000
PSI |
MMTA0580 |
|
N/A |
N/A |
14 |
70 |
0.035 |
N/A |
D1470 |
|
N/A |
N/A |
0 |
210 |
0.035 |
N/A |
J3FC-SS
C 210-035 |
|
18.0 |
5.0 |
7 |
80 |
0.035 |
4.0 |
MTK185 |
BMK18 |
|
18.0 |
5.0 |
7 |
80 |
0.035 |
4.0 |
REMC185 |
|
N/A |
N/A |
5 |
80 |
0.035 |
1000
PSI |
MMTA0580 |
|
N/A |
N/A |
14 |
70 |
0.035 |
N/A |
D1470 |
|
N/A |
N/A |
0 |
210 |
0.035 |
N/A |
J3FC-SS
C 210-035 |
|
20.0 |
5.0 |
7 |
80 |
0.035 |
4.0 |
MTK205 |
BMK20 |
|
20.0 |
5.0 |
7 |
80 |
0.035 |
4.0 |
REMC205 |
|
N/A |
N/A |
5 |
80 |
0.035 |
1000
PSI |
MMTA0580 |
|
N/A |
N/A |
14 |
70 |
0.035 |
N/A |
D1470 |
|
N/A |
N/A |
0 |
210 |
0.035 |
N/A |
J3FC-SS
C 210-035 |
Scientific Literature Papers
Mitral dilatation with
the Multi-Track system: an alternative approach.
Bonhoeffer P, Piechaud JF, Sidi D, Yonga G, Jowi C, Joshi M, Mugo M,
Kachaner J, Parenzan L.
Cathet Cardiovasc Diagn. 1995 Oct;36(2):189-93.
Percutaneous mitral
valve dilatation with the Multi-Track System.
Bonhoeffer P, Esteves C, Casal U, Tortoledo F, Yonga G, Patel T, Chisholm
R, Luxereau P, Ruiz C.
Catheter Cardiovasc Interv. 1999 Oct;48(2):178-83
The multi-track
angiography catheter: a new tool for complex catheterization in
congenital heart disease.
Bonhoeffer P, Piechaud JF, Stumper O, Bonnet D, Aggoun Y, Sidi, D,
Kachaner J.
Heart 1996 Aug;76(2):173-7
Percutaneous balloon
mitral valvotomy: initial experience in Nairobi using a multi-track
catheter system.
Yonga GO, Bonhoeffer P, Jowi CA.
East Afr Med J. 1999 Feb;76(2):71-4.
Percutaneous
transvenous mitral commissurotomy in juvenile mitral stenosis
Yonga, GO, Bonhoeffer P.
East Afr Med J. 2003 Apr;80(4):172-4.
To
purchase or for more information, call Baylis Medical at 1-800-850-9801 This publication could
include technical or other inaccuracies or typographical errors. Changes
are periodically added to the information herein; these changes will be
incorporated in the new editions of the publication. NuMED Incorporated
may make improvements and/or changes in the product(s) and/or the
program(s) described in this publication at any time. |