BIB®
Dilatation
catheter
All Catheters have:
An inner balloon 1/2 of the balloon diameter of the outer
balloon. i.e. BB010 has an 8.0 mm inner balloon.
An inner balloon that is 1.0 cm shorter than the outer
balloon. i.e. BB010 has an inner balloon that is 2.0 cm long.
An inner balloon with a rated burst pressure of 4.5 to
5.0 atmospheres. Four image bands that match the functional length of
each balloon.
A length of 110 cm.
All Catheters are for use with a 0.035" wire.
BIB®
Outer Balloon Specifications
|
Balloon
Diameter
(MM) |
Balloon
Length
(CM) |
Introducer
Size
(FR) |
Shaft
Size
(FR) |
Usable
Length
(CM) |
Guide
Wire
(Inches) |
Rated
Burst
(ATM) |
Catalog
No. |
|
8.0 |
2.5 |
8 |
8 |
110 |
0.035 |
10 |
BB001 |
|
8.0 |
3.0 |
8 |
8 |
110 |
0.035 |
10 |
BB004 |
|
8.0 |
3.5 |
8 |
8 |
110 |
0.035 |
10 |
BB007 |
|
8.0 |
4.0 |
8 |
8 |
110 |
0.035 |
10 |
BB043 |
|
8.0 |
4.5 |
8 |
8 |
110 |
0.035 |
10 |
BB044 |
|
8.0 |
5.0 |
8 |
8 |
110 |
0.035 |
10 |
BB045 |
|
8.0 |
5.5 |
8 |
8 |
110 |
0.035 |
10 |
BB046 |
|
10.0 |
2.5 |
8 |
8 |
110 |
0.035 |
9 |
BB002 |
|
10.0 |
3.0 |
8 |
8 |
110 |
0.035 |
9 |
BB005 |
|
10.0 |
3.5 |
8 |
8 |
110 |
0.035 |
9 |
BB008 |
|
10.0 |
4.0 |
8 |
8 |
110 |
0.035 |
9 |
BB047 |
|
10.0 |
4.5 |
8 |
8 |
110 |
0.035 |
9 |
BB048 |
|
10.0 |
5.0 |
8 |
8 |
110 |
0.035 |
9 |
BB049 |
|
10.0 |
5.5 |
8 |
8 |
110 |
0.035 |
9 |
BB050 |
|
12.0 |
2.5 |
8 |
8 |
110 |
0.035 |
7 |
BB003 |
|
12.0 |
3.0 |
8 |
8 |
110 |
0.035 |
7 |
BB006 |
|
12.0 |
3.5 |
8 |
8 |
110 |
0.035 |
7 |
BB009 |
|
12.0 |
4.0 |
8 |
8 |
110 |
0.035 |
7 |
BB033 |
|
12.0 |
4.5 |
8 |
8 |
110 |
0.035 |
7 |
BB037 |
|
12.0 |
5.0 |
8 |
8 |
110 |
0.035 |
7 |
BB034 |
|
12.0 |
5.5 |
8 |
8 |
110 |
0.035 |
7 |
BB051 |
|
14.0 |
2.5 |
8 |
8 |
110 |
0.035 |
6 |
BB022 |
|
14.0 |
3.0 |
8 |
8 |
110 |
0.035 |
6 |
BB052 |
|
14.0 |
3.5 |
8 |
8 |
110 |
0.035 |
6 |
BB025 |
|
14.0 |
4.0 |
8 |
8 |
110 |
0.035 |
6 |
BB038 |
|
14.0 |
4.5 |
8 |
8 |
110 |
0.035 |
6 |
BB035 |
|
14.0 |
5.0 |
8 |
8 |
110 |
0.035 |
6 |
BB039 |
|
14.0 |
5.5 |
8 |
8 |
110 |
0.035 |
6 |
BB053 |
|
15.0 |
2.5 |
9 |
9 |
110 |
0.035 |
5 |
BB054 |
|
15.0 |
3.0 |
9 |
9 |
110 |
0.035 |
5 |
BB055 |
|
15.0 |
3.5 |
9 |
9 |
110 |
0.035 |
5 |
BB056 |
|
15.0 |
4.0 |
9 |
9 |
110 |
0.035 |
5 |
BB057 |
|
15.0 |
4.5 |
9 |
9 |
110 |
0.035 |
5 |
BB058 |
|
15.0 |
5.0 |
9 |
9 |
110 |
0.035 |
5 |
BB059 |
|
15.0 |
5.5 |
9 |
9 |
110 |
0.035 |
5 |
BB060 |
|
16.0 |
2.5 |
9 |
9 |
110 |
0.035 |
5 |
BB023 |
|
16.0 |
3.0 |
9 |
9 |
110 |
0.035 |
5 |
BB010 |
|
16.0 |
3.5 |
9 |
9 |
110 |
0.035 |
5 |
BB026 |
|
16.0 |
4.0 |
9 |
9 |
110 |
0.035 |
5 |
BB013 |
|
16.0 |
4.5 |
9 |
9 |
110 |
0.035 |
5 |
BB016 |
|
16.0 |
5.0 |
9 |
9 |
110 |
0.035 |
5 |
BB028 |
|
16.0 |
5.5 |
9 |
9 |
110 |
0.035 |
5 |
BB019 |
|
18.0 |
2.5 |
10 |
9 |
110 |
0.035 |
4 |
BB024 |
|
18.0 |
3.0 |
10 |
9 |
110 |
0.035 |
4 |
BB040 |
|
18.0 |
3.5 |
10 |
9 |
110 |
0.035 |
4 |
BB027 |
|
18.0 |
4.0 |
10 |
9 |
110 |
0.035 |
4 |
BB041 |
|
18.0 |
4.5 |
10 |
9 |
110 |
0.035 |
4 |
BB029 |
|
18.0 |
5.0 |
10 |
9 |
110 |
0.035 |
4 |
BB030 |
|
18.0 |
5.5 |
10 |
9 |
110 |
0.035 |
4 |
BB031 |
|
20.0 |
3.0 |
10 |
9 |
110 |
0.035 |
4 |
BB011 |
|
20.0 |
3.5 |
10 |
9 |
110 |
0.035 |
4 |
BB042 |
|
20.0 |
4.0 |
10 |
9 |
110 |
0.035 |
4 |
BB014 |
|
20.0 |
4.5 |
10 |
9 |
110 |
0.035 |
4 |
BB017 |
|
20.0 |
5.0 |
10 |
9 |
110 |
0.035 |
4 |
BB032 |
|
20.0 |
5.5 |
10 |
9 |
110 |
0.035 |
4 |
BB020 |
|
22.0 |
3.0 |
11 |
9 |
110 |
0.035 |
3 |
BB061 |
|
22.0 |
3.5 |
11 |
9 |
110 |
0.035 |
3 |
BB062 |
|
22.0 |
4.0 |
11 |
9 |
110 |
0.035 |
3 |
BB063 |
|
22.0 |
4.5 |
11 |
9 |
110 |
0.035 |
3 |
BB064 |
|
22.0 |
5.0 |
11 |
9 |
110 |
0.035 |
3 |
BB065 |
|
22.0 |
5.5 |
11 |
9 |
110 |
0.035 |
3 |
BB066 |
|
24.0 |
3.0 |
11 |
9 |
110 |
0.035 |
3 |
BB012 |
|
24.0 |
3.5 |
11 |
9 |
110 |
0.035 |
3 |
BB067 |
|
24.0 |
4.0 |
11 |
9 |
110 |
0.035 |
3 |
BB015 |
|
24.0 |
4.5 |
11 |
9 |
110 |
0.035 |
3 |
BB018 |
|
24.0 |
5.0 |
11 |
9 |
110 |
0.035 |
3 |
BB036 |
|
24.0 |
5.5 |
11 |
9 |
110 |
0.035 |
3 |
BB021 |
To purchase or for
more information, call NuMED, Inc. at (315) 328-4491
This publication could
include technical or other inaccuracies or typographical errors. Changes
are periodically added to the information herein; these changes will be
incorporated in the new editions of the publication. NuMED Incorporated
may make improvements and/or changes in the product(s) and/or the
program(s) described in this publication at any time. |