TYSHAK II ®
Percutaneous
Transluminal
Valvuloplasty catheter
Tyshak II® Specifications (Cont'd)
|
Balloon
Diameter
(MM) |
Balloon
Length
(CM) |
Introducer
Size
(FR) |
Shaft
Size
(FR) |
Usable
Length
(CM) |
Guide
Wire
(Inches) |
Rated
Burst
(ATM) |
*Nominal
Pressure
(ATM) |
Catalog
No. |
|
12.0 |
5.0 |
5 |
5 |
90 |
0.025 |
3.5 |
3 |
SO033 |
|
12.0 |
6.0 |
6 |
6 |
90 |
0.035 |
3.5 |
3 |
SO004 |
|
13.0 |
2.0 |
6 |
6 |
100 |
0.035 |
3 |
2.5 |
SO035 |
|
13.0 |
3.0 |
6 |
6 |
100 |
0.035 |
3 |
2.5 |
SO036 |
|
13.0 |
4.0 |
6 |
6 |
100 |
0.035 |
3 |
2.5 |
SO034 |
|
13.0 |
5.0 |
6 |
6 |
100 |
0.035 |
3 |
2.5 |
SO069 |
|
14.0 |
2.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
SO018 |
|
14.0 |
3.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC511 |
|
14.0 |
4.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC512 |
|
14.0 |
5.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC513 |
|
14.0 |
6.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC514 |
|
15.0 |
3.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC515 |
|
15.0 |
4.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC516 |
|
15.0 |
5.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC517 |
|
15.0 |
6.0 |
7 |
7 |
100 |
0.035 |
3 |
2 |
PDC518 |
|
16.0 |
2.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
SN002 |
|
16.0 |
3.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC519 |
|
16.0 |
4.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC520 |
|
16.0 |
5.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC521 |
|
16.0 |
6.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC522 |
|
17.0 |
3.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC523 |
|
17.0 |
4.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC524 |
|
17.0 |
5.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC525 |
|
17.0 |
6.0 |
7 |
7 |
100 |
0.035 |
2.5 |
2 |
PDC526 |
|
18.0 |
3.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC527 |
|
18.0 |
4.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC528 |
|
18.0 |
5.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC529 |
|
18.0 |
6.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC530 |
|
20.0 |
2.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
SN001 |
|
20.0 |
3.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC531 |
|
20.0 |
4.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC532 |
|
20.0 |
5.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC533 |
|
20.0 |
6.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC534 |
|
22.0 |
2.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
SN013 |
|
22.0 |
3.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC535 |
|
22.0 |
4.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC536 |
|
22.0 |
5.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC537 |
|
22.0 |
6.0 |
8 |
8 |
100 |
0.035 |
2 |
1.5 |
PDC538 |
|
23.0 |
3.0 |
9 |
9 |
100 |
0.035 |
2 |
1.5 |
PDC539 |
|
23.0 |
4.0 |
9 |
9 |
100 |
0.035 |
2 |
1.5 |
PDC540 |
|
23.0 |
5.0 |
9 |
9 |
100 |
0.035 |
2 |
1.5 |
PDC541 |
|
23.0 |
6.0 |
9 |
9 |
100 |
0.035 |
2 |
1.5 |
PDC542 |
|
25.0 |
3.0 |
9 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC543 |
|
25.0 |
4.0 |
9 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC544 |
|
25.0 |
5.0 |
9 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC545 |
|
25.0 |
6.0 |
9 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC546 |
|
30.0 |
3.0 |
10 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC547 |
|
30.0 |
4.0 |
10 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC548 |
|
30.0 |
5.0 |
10 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC549 |
|
30.0 |
6.0 |
10 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC550 |
|
30.0 |
10.0 |
10 |
9 |
100 |
0.035 |
1.5 |
1 |
PDC552 |
To
purchase or for more information, call Baylis Medical at 1-800-850-9801
* Pressure at which balloon will
not exceed 10% of nominal size.
This publication could
include technical or other inaccuracies or typographical errors. Changes
are periodically added to the information herein; these changes will be
incorporated in the new editions of the publication. NuMED Incorporated
may make improvements and/or changes in the product(s) and/or the
program(s) described in this publication at any time. |